{"product_id":"aciq-1-5-ton-18-5-seer2-wall-mount-heat-pump-split-system-inverter-r454b","title":"ACiQ 1.5 Ton 18.5 SEER2 Wall Mount Heat Pump Split System Inverter R454B","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACIQ Standard Series 1.5 Ton 18.8 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter ACIQ-18-EHPD\u003c\/h3\u003e\n\u003cp\u003eThe ACIQ-18-EHPD is a 1.5-ton high-efficiency inverter heat pump condenser engineered to deliver dependable, year-round comfort. Rated at 18.8 SEER2 and pre-charged with R454B refrigerant, this condenser uses inverter technology to convert AC power to DC, allowing the compressor to continuously adjust its speed and modify BTU output based on real-time demand for efficient, adaptable performance across varying weather conditions.\u003c\/p\u003e\n\u003cp\u003eEquipped with advanced sensors, this condenser monitors indoor and outdoor air temperature, duct pressure, refrigerant temperature, and overall performance. During initial startup it enters a learning mode, collecting and storing data to optimize future operation. Its self-adjusting, adaptive sizing design allows the unit to function like a smaller unit when full heating capacity isn't needed, helping maintain ideal cooling performance and humidity control.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1.5 ton inverter heat pump condenser for ducted HVAC systems\u003c\/li\u003e\n\u003cli\u003e18.8 SEER2 high-efficiency performance with 9.1 HSPF2 and 11.0 EER2\u003c\/li\u003e\n\u003cli\u003eVariable-speed compressor delivers 12,000-18,000 BTU of adjustable heating and cooling output based on demand\u003c\/li\u003e\n\u003cli\u003eLearning condenser technology that monitors performance and self-optimizes after initial startup\u003c\/li\u003e\n\u003cli\u003eAdaptive sizing automatically adjusts output to actual demand for balanced comfort and humidity control\u003c\/li\u003e\n\u003cli\u003ePre-charged with R454B refrigerant\u003c\/li\u003e\n\u003cli\u003eEfficient cooling from -13°F to 122°F outdoor temperatures\u003c\/li\u003e\n\u003cli\u003eReliable heating from -13°F to 75°F outdoor temperatures\u003c\/li\u003e\n\u003cli\u003eDurable gold fin condenser coil coating for longevity\u003c\/li\u003e\n\u003cli\u003eQuiet operation, even under high workloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Overview\u003c\/h3\u003e\n\u003cp\u003eWith a 1.5-ton capacity and an 18.8 SEER2 efficiency rating, the ACIQ-18-EHPD provides versatile comfort across a range of climates with a variable output that eliminates short cycling for lasting efficiency. Efficiency at lower temperatures varies by climate — at 0°F outdoor temperature, this heat pump operates at 58% efficiency, making it a strong fit for moderate climates that experience some colder days.\u003c\/p\u003e\n\u003cp\u003ePlease note that this condenser cannot operate independently and must be installed with a compatible indoor air handler.\u003c\/p\u003e\n\u003ch3\u003eImportant Refrigerant Safety Notice\u003c\/h3\u003e\n\u003cp\u003eThis condenser uses R454B refrigerant, classified as an A2L refrigerant. To comply with safety standards and maintain warranty coverage, the unit must be paired with an R454B-compatible air handler equipped with a refrigerant leak detection system. Failure to follow these requirements may result in safety hazards and could void the manufacturer warranty. For compatibility questions, please call 1-888-557-9206.\u003c\/p\u003e\n\n\u003ch3\u003eACIQ 1.5 Ton Ducted Air Handler Wall Mounted - R454B ACIQ-18W-WMB\u003c\/h3\u003e\n\u003cp\u003eThe ACIQ-18W-WMB Wall Mounted Ducted Air Handler is designed for vertical wall or stud mounting, giving installers versatile placement options for multi-tenant and space-constrained applications. Encased in a fully insulated, galvanized-steel cabinet, this air handler ensures dependable performance and long-term durability.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnects to ductwork\u003c\/li\u003e\n\u003cli\u003eSuitable for use with R454B refrigerant systems\u003c\/li\u003e\n\u003cli\u003eFully adjustable TXV for cooling and heat pump operation\u003c\/li\u003e\n\u003cli\u003eDirect-drive, multi-speed motor for adjustable air volume in heating and cooling\u003c\/li\u003e\n\u003cli\u003eFactory-installed pull-type disconnect for convenience\u003c\/li\u003e\n\u003cli\u003eAluminum tube coils included\u003c\/li\u003e\n\u003cli\u003eThermoplastic drain pan with bottom primary and secondary drain connections\u003c\/li\u003e\n\u003cli\u003eBuilt-in filter rack with filter for improved indoor air quality\u003c\/li\u003e\n\u003cli\u003eWall-hanging bracket included for easy installation\u003c\/li\u003e\n\u003cli\u003eWorks with ACiQ's high-efficiency inverter condensers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Overview\u003c\/h3\u003e\n\u003cp\u003eRated at 1.5 tons, the ACIQ-18W-WMB is designed for vertical wall mounting with an up-flow-only configuration. Your technician will handle electrical, refrigerant, thermostat, and communication connections, as well as connecting to the return and supply ductwork. Any 24V thermostat with 2 stages of heating can control the system, but the supplied thermostat is recommended. Optional 3 kW, 5 kW, 8 kW, or 10 kW electric heat strips can be added for backup heat on the coldest days, and the intelligent control board displays fault codes if maintenance is needed.\u003c\/p\u003e\n\u003cp\u003eNOTE: to function as a heat pump, this air handler must be installed with a condenser and other installation equipment. To use straight electric heating, an electric heater coil is required and is available at an additional cost.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/hvacstore.com\/collections\/multi-tenant-heat-systems\" title=\"Multi Tenant Heat Systems\"\u003e\u003cstrong\u003eView More Multi Tenant Heat Systems\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACIQ Standard Series 1.5 Ton 18.8 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter ACIQ-18-EHPD\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%; text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACiQ\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACIQ-18-EHPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e51.15 oz.\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e83.77 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eReplaces\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACIQ-18-EHPB\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e18,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e18,000 BTU\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMaximum CFM\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e1450.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e55\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectric Heat\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eHeat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eR454B\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e9.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSEER2\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e18.8\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eEER2\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCondenser Stages\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eVariable Speed\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eRotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eLiquid Valve Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/8\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSuction Valve Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e208\/230V, 1 Phase, 60 Hz\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e20 Amps\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e16 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eTonnage\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e1.5 Ton\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin\/Max Outdoor Temp for Heating\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e-13°F - 75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin\/Max Outdoor Temp for Cooling\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e-13°F - 122°F\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eZone Compatibility\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e-13°F - 122°F\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e21.81\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e31.69\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e12.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"height: 50px;\"\u003e12 Years Compressor and 7 Years Parts with Online Registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eACIQ 1.5 Ton Ducted Air Handler Wall Mounted - R454B ACIQ-18W-WMB\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%; text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACiQ\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACIQ-18W-WMB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e111.33 lbs\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBlower Motor\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eMulti Speed Direct Drive Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMaximum CFM\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e618\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e48 decibels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectric Backup Heat Capabilities\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3 Kilowatts, 5 Kilowatts, 8 Kilowatts, 10 Kilowatts\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eUpflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eR454B\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eLiquid Line\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSuction Line\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e208\/230v 1 Phase 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e15 Amps\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e4 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eTonnage\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e1.5 Ton\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e36.54\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e20.28\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e15.71\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"height: 50px;\"\u003e7 year parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACIQ Standard Series 1.5 Ton 18.8 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter ACIQ-18-EHPD\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; text-align: center; border: 1px solid black; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eWarranty Type\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eCompressor\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eParts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eRegistered Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e12 years\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e7 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eACIQ 1.5 Ton Ducted Air Handler Wall Mounted - R454B ACIQ-18W-WMB\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; text-align: center; border: 1px solid black; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eWarranty Type\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eParts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eRegistered Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e7 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACIQ Standard Series 1.5 Ton 18.8 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter ACIQ-18-EHPD\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ_Quick_Start_Guide_2025_Gen2_R454B_1-Sheeter_V4.pdf?v=1784175721\"\u003e\u003cstrong\u003eSystem Quick Start Guide\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-HPD-EHPD-ACB-Brochure.pdf?v=1784175736\"\u003e\u003cstrong\u003eACiQ-HPD-EHPD-ACB Brochure\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-AHRI-18-AHD-18-EHPD-031725.pdf?v=1784175742\"\u003e\u003cstrong\u003e1.5 Ton EHPD \/ AHD AHRI Certificate\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-AHD-NCL-Sub-18K-AHD-18K-EHPD-122424.pdf?v=1784175748\"\u003e\u003cstrong\u003e1.5 Ton EHPD \/ AHD Submittal\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-HPD-EHPD-im-en-01-022625_16123000A33051.pdf?v=1784175762\"\u003e\u003cstrong\u003eCondenser Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-HPD-EHPD-sm-en-01-061825_NB_H_241119_41-12K-60K-EHPD-HPD.pdf?v=1784175793\"\u003e\u003cstrong\u003eCondenser Service Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-18K-AHD-18K-EHPD-EPT-en-01-041025.pdf?v=1784175799\"\u003e\u003cstrong\u003e1.5 Ton EHPD \/ AHD Extended Performance Tables\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-AHD-EHPD-HPD-Nominal-Capacity-Performance-Chart-040825.pdf?v=1784175806\"\u003e\u003cstrong\u003eEHPD \/ HPD \/ AHD \/ PAH Nominal Capacity Performance Chart\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ_24v_Warning_2025_v1.pdf?v=1784175812\"\u003e\u003cstrong\u003eACiQ 24 Volt Wiring Notice\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/aciq-mini-split-HES-warranty-12YR-Edit-2-8-4-2-1.pdf?v=1784175820\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eACIQ 1.5 Ton Ducted Air Handler Wall Mounted - R454B ACIQ-18W-WMB\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-WMAHU-Sub-18W-WMB-18-HPD-061625.pdf?v=1784175910\"\u003e\u003cstrong\u003e1.5 Ton HPD \/ WMB Submittal\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-WMAHU-Sub-18W-WMB-18-EHPD-102024.pdf?v=1784175916\"\u003e\u003cstrong\u003e1.5 Ton EHPD \/ WMB Submittal\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-CIS-W-WMB-im-en-01-040625_16123100000988.pdf?v=1784175944\"\u003e\u003cstrong\u003eWall-Mount Air Handler Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-CIS-W-WMB-om-en-01-093024_16123100001008.pdf?v=1784175950\"\u003e\u003cstrong\u003eWall-Mount Air Handler Owner's Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-CIS-W-WMB-sm-en-01-123124_NA_H_241231.pdf?v=1784175969\"\u003e\u003cstrong\u003eWall-Mount Air Handler Service Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-18W-WMB-18-HPD-EPT-en-01-111224.pdf?v=1784175974\"\u003e\u003cstrong\u003e1.5 Ton HPD \/ WMB Performance Table\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-18W-WMB-18-EHPD-EPT-en-01-102024.pdf?v=1784175979\"\u003e\u003cstrong\u003e1.5 Ton EHPD \/ WMB Performance Table\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-W-PB-W-WMB-Remote-Controller-Manual.pdf?v=1784175902\"\u003e\u003cstrong\u003eRemote Controller Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ACiQ","offers":[{"title":"Default Title","offer_id":67373839712560,"sku":"ACIQ-18-EHPD \/ ACIQ-18W-WMB","price":2400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-18-EHPD_ACIQ-18W-WMB.webp?v=1784181206","url":"https:\/\/hvacstore.com\/products\/aciq-1-5-ton-18-5-seer2-wall-mount-heat-pump-split-system-inverter-r454b","provider":"HVAC Store","version":"1.0","type":"link"}