Skip to content
September Sale Is Live! | Click Or Call 833-658-3387

ACiQ 1 Ton 17.5 SEER2 Heat Pump Split System Multi-Positional R410A

By ACiQ | Model: ACIQ-12-EHPB / ACIQ-12-AHB | ID: 902651
No Sales Tax - in most states excluding California
Manufacturer Warranty Included
Satisfaction Guarantee - or return within 30 Days
Most Products In Stock - Call or Text (833) 658-3387 for availability
$2,100.00 + FREE SHIPPING

ADD TO CART FOR BEST PRICE

Working on a big project?
Free Shipping On Orders $1000 See our shipping policy
Flexible Financing Finance with Affirm. See terms
Lowest Price Guarantee Find it cheaper? We'll match it. See terms
Speak with an Expert Call us at (833) 658-3387

Important Installation Note: This is a professional-grade, non-DIY system (including ACiQ, Goodman, Daikin, and select MrCool systems). It's recommended that installation and configuration is done by a licensed HVAC technician to ensure correct setup, safety compliance, and to maintain your manufacturer warranty coverage.

Product Details

ACiQ 1 Ton 17.5 SEER2 Central Heat Pump Condenser Inverter R410A ACIQ-12-EHPB

The ACIQ-12-EHPB is a 1 Ton single-stage heat pump condenser built around a scroll compressor, rated for 12,000 BTU of cooling and 13,000 BTU of heating at 17.5 SEER2 / 9 HSPF2. It ships pre-charged with enough R454B refrigerant for a 15-foot line set, so a straightforward line-set connection is all that's needed to bring the system online.

Key Features

  • 1 Ton Scroll Compressor - Single-stage cooling and heat pump heating rated at 17.5 SEER2.
  • 12,000 BTU Cooling / 13,000 BTU Heating - Sized for mobile and manufactured home split systems.
  • Factory Pre-Charged - Comes charged for a 15-foot line set, simplifying installation.
  • 208/230V, 1 Phase, 60 Hz Electrical - Runs on a standard single-phase circuit with a 109.13 lb cabinet.
  • R454B Refrigerant - Uses the lower-GWP refrigerant required for current equipment.
  • Heat Pump Operation - Provides both cooling and supplemental electric-backup-free heating down to roughly 35°F outdoor temperature.

ACiQ 1 Ton Multi-Positional Air Handler R410A ACIQ-12-AHB

The ACIQ-12-AHB is a 1 Ton multi-positional air handler rated for 12,000 BTU of airflow capacity, built to pair with a compatible ACiQ heat pump condenser. A Variable Speed ECM blower and a factory-installed TXV kit make it a flexible fit for upflow, downflow, or horizontal installations.

Key Features

  • 1 Ton Multi-Positional Design - Installs upflow, downflow, or horizontal.
  • Variable Speed ECM - Delivers consistent airflow and quieter operation.
  • Factory TXV Kit - Pre-installed for accurate refrigerant metering.
  • Optional Electric Backup Heat - Supports 5/8/10/15/20 kW heat kits, sold separately.
  • 127.43 lb Cabinet - One-piece outer casing with a corrosion-resistant aluminum coil.

View More Heat Pump Systems

Specifications

ACiQ 1 Ton 17.5 SEER2 Central Heat Pump Condenser Inverter R410A ACIQ-12-EHPB

Brand ACiQ SKU ACIQ-12-EHPB
Refrigerant Charge 25' Weight (in lbs) 109.13
Cooling BTU 12,000 BTU Heating BTU 13,000 BTU
Maximum CFM 617.65 Decibel Level (dBA) 34
Refrigerant R410A HSPF2 9
SEER2 (Efficiency) 17.5 EER2 11.3
Condenser Stages Variable Speed Compressor Type Rotary
Liquid Valve Size 3/8" Suction Valve Size 3/4"
Electrical 208/230V, 1 Phase, 60 Hz Max Breaker Size 20 Amps
Min. Breaker Size 16 Amps Tonnage 1 Ton
Mini Split Type Multi-Positional Min/Max Outdoor Temp for Heating 5°F to 75°F
Min/Max Outdoor Temp for Cooling 5°F to 122°F Height 45"
Width 21.02" Depth 17.52"

ACiQ 1 Ton Multi-Positional Air Handler R410A ACIQ-12-AHB

Brand ACiQ SKU ACIQ-12-AHB
Weight (in lbs) 127.43 Cooling BTU 12,000 BTU
Heating BTU 13,000 BTU Blower Variable Speed ECM
Maximum CFM 1450 Decibel Level (dBA) 52
Optional Electric Heat 5 or 10 Kilowatts Energy Star Yes
Refrigerant R410A HSPF 9
SEER2 (Efficiency) 17 EER2 11.3
Liquid Line Size 3/8" Suction Line Size 3/4"
Electrical 208/230V, 1 Phase, 60 Hz Max Breaker Size 20 Amps
Min. Breaker Size 16 Amps Tonnage 1 Ton
Configuration Multi-Positional Height 21.81"
Width 31.69" Depth 12.99"
AHRI Certificate # 208106635
Warranty

ACiQ 1 Ton 17.5 SEER2 Central Heat Pump Condenser Inverter R410A ACIQ-12-EHPB

Warranty Type Parts Compressor
Standard Warranty 5 years 5 years
Registered Warranty 7 years 12 years

ACiQ 1 Ton Multi-Positional Air Handler R410A ACIQ-12-AHB

Warranty Type Parts
Standard Warranty 7 years
Shipping

We ship freight to the 48 contiguous states, excluding Hawaii and Alaska. Some shipping restrictions may apply. Liftgate services may incur an additional fee, which can be added at checkout.

Order Processing: Orders are processed within 1-3 business days (excluding weekends). Orders placed on Fridays will be processed the next business day. Once shipped, you’ll receive an email confirmation with tracking details. Backordered products may have longer processing times, and we will notify you of any delays.

Arrival of Goods: Freight delivery times depend on the carrier's schedule and routing. Estimated delivery times are provided at checkout. The carrier will contact you to arrange delivery, and you must be present to sign for the shipment.

Damages: Upon delivery, inspect your shipment carefully for any damage or discrepancies. Note any issues on the carrier’s delivery receipt and notify us within 24 hours. Claims made after this timeframe may be denied. Photographic proof is required for processing claims. Report damages or discrepancies immediately at [email protected].

Returns: For returns unrelated to damage, contact us at [email protected] for authorization. Return shipping costs are the customer’s responsibility, and a 20% restocking fee applies. Items must be in original packaging and condition for a refund.

Delivery Receipt: Before signing the delivery receipt, inspect the shipment for any damage. Your signature confirms acceptance of the delivery unless issues are noted.

Policy Updates: Our shipping policy may change, and updates will be communicated via our website or other channels. For any questions, contact The HVAC Store at [email protected] or call (833) 658-3387.

Reviews

Product Q&A

Have a specific question?

Be the first to ask a question about this product.

Our Real Customer Reviews

See what our customers have said about us.

Product Details

ACiQ 1 Ton 17.5 SEER2 Central Heat Pump Condenser Inverter R410A ACIQ-12-EHPB

The ACIQ-12-EHPB is a 1 Ton single-stage heat pump condenser built around a scroll compressor, rated for 12,000 BTU of cooling and 13,000 BTU of heating at 17.5 SEER2 / 9 HSPF2. It ships pre-charged with enough R454B refrigerant for a 15-foot line set, so a straightforward line-set connection is all that's needed to bring the system online.

Key Features

  • 1 Ton Scroll Compressor - Single-stage cooling and heat pump heating rated at 17.5 SEER2.
  • 12,000 BTU Cooling / 13,000 BTU Heating - Sized for mobile and manufactured home split systems.
  • Factory Pre-Charged - Comes charged for a 15-foot line set, simplifying installation.
  • 208/230V, 1 Phase, 60 Hz Electrical - Runs on a standard single-phase circuit with a 109.13 lb cabinet.
  • R454B Refrigerant - Uses the lower-GWP refrigerant required for current equipment.
  • Heat Pump Operation - Provides both cooling and supplemental electric-backup-free heating down to roughly 35°F outdoor temperature.

ACiQ 1 Ton Multi-Positional Air Handler R410A ACIQ-12-AHB

The ACIQ-12-AHB is a 1 Ton multi-positional air handler rated for 12,000 BTU of airflow capacity, built to pair with a compatible ACiQ heat pump condenser. A Variable Speed ECM blower and a factory-installed TXV kit make it a flexible fit for upflow, downflow, or horizontal installations.

Key Features

  • 1 Ton Multi-Positional Design - Installs upflow, downflow, or horizontal.
  • Variable Speed ECM - Delivers consistent airflow and quieter operation.
  • Factory TXV Kit - Pre-installed for accurate refrigerant metering.
  • Optional Electric Backup Heat - Supports 5/8/10/15/20 kW heat kits, sold separately.
  • 127.43 lb Cabinet - One-piece outer casing with a corrosion-resistant aluminum coil.

View More Heat Pump Systems

Specifications

ACiQ 1 Ton 17.5 SEER2 Central Heat Pump Condenser Inverter R410A ACIQ-12-EHPB

Brand ACiQ SKU ACIQ-12-EHPB
Refrigerant Charge 25' Weight (in lbs) 109.13
Cooling BTU 12,000 BTU Heating BTU 13,000 BTU
Maximum CFM 617.65 Decibel Level (dBA) 34
Refrigerant R410A HSPF2 9
SEER2 (Efficiency) 17.5 EER2 11.3
Condenser Stages Variable Speed Compressor Type Rotary
Liquid Valve Size 3/8" Suction Valve Size 3/4"
Electrical 208/230V, 1 Phase, 60 Hz Max Breaker Size 20 Amps
Min. Breaker Size 16 Amps Tonnage 1 Ton
Mini Split Type Multi-Positional Min/Max Outdoor Temp for Heating 5°F to 75°F
Min/Max Outdoor Temp for Cooling 5°F to 122°F Height 45"
Width 21.02" Depth 17.52"

ACiQ 1 Ton Multi-Positional Air Handler R410A ACIQ-12-AHB

Brand ACiQ SKU ACIQ-12-AHB
Weight (in lbs) 127.43 Cooling BTU 12,000 BTU
Heating BTU 13,000 BTU Blower Variable Speed ECM
Maximum CFM 1450 Decibel Level (dBA) 52
Optional Electric Heat 5 or 10 Kilowatts Energy Star Yes
Refrigerant R410A HSPF 9
SEER2 (Efficiency) 17 EER2 11.3
Liquid Line Size 3/8" Suction Line Size 3/4"
Electrical 208/230V, 1 Phase, 60 Hz Max Breaker Size 20 Amps
Min. Breaker Size 16 Amps Tonnage 1 Ton
Configuration Multi-Positional Height 21.81"
Width 31.69" Depth 12.99"
AHRI Certificate # 208106635
Warranty

ACiQ 1 Ton 17.5 SEER2 Central Heat Pump Condenser Inverter R410A ACIQ-12-EHPB

Warranty Type Parts Compressor
Standard Warranty 5 years 5 years
Registered Warranty 7 years 12 years

ACiQ 1 Ton Multi-Positional Air Handler R410A ACIQ-12-AHB

Warranty Type Parts
Standard Warranty 7 years
Shipping

We ship freight to the 48 contiguous states, excluding Hawaii and Alaska. Some shipping restrictions may apply. Liftgate services may incur an additional fee, which can be added at checkout.

Order Processing: Orders are processed within 1-3 business days (excluding weekends). Orders placed on Fridays will be processed the next business day. Once shipped, you’ll receive an email confirmation with tracking details. Backordered products may have longer processing times, and we will notify you of any delays.

Arrival of Goods: Freight delivery times depend on the carrier's schedule and routing. Estimated delivery times are provided at checkout. The carrier will contact you to arrange delivery, and you must be present to sign for the shipment.

Damages: Upon delivery, inspect your shipment carefully for any damage or discrepancies. Note any issues on the carrier’s delivery receipt and notify us within 24 hours. Claims made after this timeframe may be denied. Photographic proof is required for processing claims. Report damages or discrepancies immediately at [email protected].

Returns: For returns unrelated to damage, contact us at [email protected] for authorization. Return shipping costs are the customer’s responsibility, and a 20% restocking fee applies. Items must be in original packaging and condition for a refund.

Delivery Receipt: Before signing the delivery receipt, inspect the shipment for any damage. Your signature confirms acceptance of the delivery unless issues are noted.

Policy Updates: Our shipping policy may change, and updates will be communicated via our website or other channels. For any questions, contact The HVAC Store at [email protected] or call (833) 658-3387.

Reviews