{"product_id":"aciq-2-5-ton-17-5-seer2-extreme-wall-mount-heat-pump-split-inverter-r454b","title":"ACiQ 2.5 Ton 17.5 SEER2 Extreme Wall Mount Heat Pump Split Inverter R454B","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACIQ 2.5 Ton 16.8 SEER2 High Efficiency Central Heat Pump | Inverter | Extreme Series - R454B (ACIQ-30-HPD)\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eInverter\u003c\/b\u003e - The ACIQ-30-HPD 2.5 ton Extreme series central inverter heat pump utilizes inverter technology to convert AC power to DC, allowing the compressor inside your condenser to speed up and slow down. This allows the system to self-adjust BTU output based on demand. As the weather changes, so will your system output.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLearning Condenser\u003c\/b\u003e - Equipped with advanced sensors, this condenser monitors indoor and outdoor air temperature, duct pressure, refrigerant temperature, and overall performance. During the initial startup, it enters a learning mode that optimizes future operations for maximum efficiency by collecting and storing data.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAdaptive Sizing\u003c\/b\u003e - With its self-adjusting inverter design, the ACIQ-30-HPD can be sized based on your heating needs. Standard heat pumps may cause discomfort during summer when sized for heat, but this unit automatically adjusts to function like a smaller unit, ensuring ideal cooling performance without excess humidity.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eExtreme Heat Technology\u003c\/b\u003e - \"Extreme Heat\" means extended temperature range heating all the way down to -22°F. Traditional heat pumps cannot produce significant heat below about 30°F outside temperature. Below that threshold, they rely on expensive backup electric heat. The ACIQ-30-HPD uses the inverter to vary the refrigerant flow, allowing for maximum heat extraction during extreme cold temperatures. The backup electric heat supplements the heat pump, and only takes over below -22°F. The heat pump gives 100% at 0°F, and still gives 80% at -22°F, saving you up to 75% on cold weather heating bills.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVariable BTU output based on demand: 12,000-30,000 BTU for cooling, 12,000-34,000 for heating\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eInverter heat pump system for ducted applications\u003c\/li\u003e\n\u003cli\u003eEfficient cooling from -22°F to 122°F outdoor temperatures\u003c\/li\u003e\n\u003cli\u003eEfficient heating from -22°F to 75°F outdoor temperatures\u003c\/li\u003e\n\u003cli\u003eDurable gold fin condenser coil coating for longevity\u003c\/li\u003e\n\u003cli\u003eQuiet operation, even under high workloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Overview\u003c\/h3\u003e\n\u003cp\u003eBoasting an efficiency rating of 16.8 SEER2, the ACIQ-30-HPD provides versatile comfort across a range of climates by providing reliable comfort with a variable output that eliminates short cycling for lasting efficiency. Not all heat pumps are built the same — depending on the climate where you live, your best fit can depend dramatically on the efficiency of the heat pump at lower temperatures. At 0°F, this heat pump operates at 95% efficiency, making it a good fit for maximizing efficiency in the coldest climates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Refrigerant Safety Notice:\u003c\/strong\u003e This system uses R454B, an A2L (mildly flammable) refrigerant. It must be paired with a compatible indoor unit equipped for A2L refrigerant handling (including leak detection where required by code). If you have questions about compatibility with an existing indoor unit or ductwork, please call 1-888-557-9206 before purchasing.\u003c\/p\u003e\n\n\u003ch3\u003eACiQ 2.5 Ton Ducted Air Handler Wall Mounted - R454B (ACIQ-30W-WMB)\u003c\/h3\u003e\n\u003cp\u003eThe ACIQ Wall Mount Ducted Air Handler is designed for vertical wall or stud mounting, giving you versatile installation options. Encased in a fully insulated, galvanized-steel cabinet, this air handler ensures dependable performance and long-term durability.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnects to ductwork\u003c\/li\u003e\n\u003cli\u003eSuitable for use with R454B refrigerants\u003c\/li\u003e\n\u003cli\u003eFully adjustable TXV for cooling and heat pump operation\u003c\/li\u003e\n\u003cli\u003eDirect-drive, multi-speed motor for adjustable air volume in heating and cooling\u003c\/li\u003e\n\u003cli\u003eFactory-installed pull-type disconnect for convenience\u003c\/li\u003e\n\u003cli\u003eAluminum tube coils included in all models\u003c\/li\u003e\n\u003cli\u003eThermoplastic drain pan with bottom primary and secondary drain connections\u003c\/li\u003e\n\u003cli\u003eBuilt-in filter rack with filter for improved indoor air quality\u003c\/li\u003e\n\u003cli\u003eWall-hanging bracket included for easy installation\u003c\/li\u003e\n\u003cli\u003eWorks with our high-efficiency inverter condensers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Overview\u003c\/h3\u003e\n\u003cp\u003eInstalling the ACIQ Wall Mount Ducted Air Handler is similar to installing any replacement air handler. Your technician will handle electrical, refrigerant, thermostat, and communication connections, as well as connecting to your return and supply ductwork. This air handler is designed for vertical wall mounting with an up-flow-only configuration. Any 24V thermostat with 2 stages of heating can control the system, but the supplied thermostat is recommended. You can add electric strip heat for backup on the coldest days. The intelligent control board displays fault codes if maintenance is needed.\u003c\/p\u003e\n\u003cp\u003eNOTE: to function as a heat pump, this air handler must be installed with a condenser and other installation equipment, available at an additional cost if not already included in this product bundle. To use straight electric heating, an electric heater coil is necessary and is also available at an additional cost.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/hvacstore.com\/collections\/multi-tenant-heat-systems\" title=\"Multi Tenant Heat Systems\"\u003e\u003cstrong\u003eView More Multi Tenant Heat Systems\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACIQ 2.5 Ton 16.8 SEER2 High Efficiency Central Heat Pump | Inverter | Extreme Series - R454B (ACIQ-30-HPD)\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%; text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACiQ\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACIQ-30-HPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e105.82 oz.\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e174.60 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eReplaces\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACIQ-30-HPB\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e30,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e34,000 BTU\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMaximum CFM\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3001.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e60.5\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectric Heat\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eHeat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eR454B\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSEER2 (Efficiency)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e16.8\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eEER2\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e11.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCondenser Stages\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eVariable Speed\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eRotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eLiquid Valve Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/8\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSuction Valve Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e208\/230V, 1 Phase, 60 Hz\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e30 Amps\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e29.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eTonnage\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e2.5 Ton\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin\/Max Outdoor Temp for Heating\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e-22°F - 75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin\/Max Outdoor Temp for Cooling\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e-22°F - 122°F\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eZone Compatibility\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e-22°F - 122°F\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e31.89\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e37.24\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e16.14\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"height: 50px;\"\u003e12 Years Compressor and 7 Years Parts with Online Registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eACiQ 2.5 Ton Ducted Air Handler Wall Mounted - R454B (ACIQ-30W-WMB)\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%; text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACiQ\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACIQ-30W-WMB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e110.23 lbs\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBlower Motor\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eMulti Speed Direct Drive Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMaximum CFM\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e988.8\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e50.5 decibels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectric Backup Heat Capabilities (Optional)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3 Kilowatts, 5 Kilowatts, 8 Kilowatts, 10 Kilowatts\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eLiquid Line\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/8\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSuction Line\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e208\/230v 1 Phase 60 Hz\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e15 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e6 Amps\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eTonnage\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e2.5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e36.5\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e20 1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"height: 50px;\"\u003e15 3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"height: 50px;\"\u003e7 years parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACIQ 2.5 Ton 16.8 SEER2 High Efficiency Central Heat Pump | Inverter | Extreme Series - R454B (ACIQ-30-HPD)\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; text-align: center; border: 1px solid black; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eWarranty Type\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eCompressor\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eParts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eRegistered Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e12 years\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e7 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eACiQ 2.5 Ton Ducted Air Handler Wall Mounted - R454B (ACIQ-30W-WMB)\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; text-align: center; border: 1px solid black; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eWarranty Type\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eParts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eRegistered Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e7 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACIQ 2.5 Ton 16.8 SEER2 High Efficiency Central Heat Pump | Inverter | Extreme Series - R454B (ACIQ-30-HPD)\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-HPD-EHPD-ACB-Brochure.pdf?v=1784175736\"\u003e\u003cstrong\u003eACiQ-HPD-EHPD-ACB Brochure\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ_Quick_Start_Guide_2025_Gen2_R454B_1-Sheeter_V4.pdf?v=1784175721\"\u003e\u003cstrong\u003eHPD \/ AHD System Quick Start Guide\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ_Quick_Start_Guide_2025_Gen3_R454B_1-Sheeter_V1.pdf?v=1784175988\"\u003e\u003cstrong\u003eHPD \/ PAH System Quick Start Guide\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-AHRI-30-AHD-30-HPD-031725.pdf?v=1784176204\"\u003e\u003cstrong\u003e2.5 Ton HPD \/ AHD AHRI Certificate\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-AHRI-30-PAH-30-HPD-031725.pdf?v=1784176210\"\u003e\u003cstrong\u003e2.5 Ton HPD \/ PAH AHRI Certificate\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-AHD-NCL-Sub-30K-AHD-30K-HPD-122424.pdf?v=1784176218\"\u003e\u003cstrong\u003e2.5 Ton HPD \/ AHD Submittal\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-PAH-NCL-Sub-30K-PAH-30K-HPD-122324.pdf?v=1784176225\"\u003e\u003cstrong\u003e2.5 Ton HPD \/ PAH Submittal\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-HPD-EHPD-im-en-01-022625_16123000A33051.pdf?v=1784175762\"\u003e\u003cstrong\u003eCondenser Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-HPD-EHPD-sm-en-01-061825_NB_H_241119_41-12K-60K-EHPD-HPD.pdf?v=1784175793\"\u003e\u003cstrong\u003eCondenser Service Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-30K-AHD-30K-HPD-EPT-en-01-041025.pdf?v=1784176230\"\u003e\u003cstrong\u003e2.5 Ton HPD \/ AHD Extended Performance Tables\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-30K-PAH-30K-HPD-EPT-en-01-070524.pdf?v=1784176236\"\u003e\u003cstrong\u003e2.5 Ton HPD \/ PAH Extended Performance Tables\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-AHD-EHPD-HPD-Nominal-Capacity-Performance-Chart-040825.pdf?v=1784175806\"\u003e\u003cstrong\u003eEHPD \/ HPD \/ AHD \/ PAH Nominal Capacity Performance Chart\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ_24v_Warning_2025_v1.pdf?v=1784175812\"\u003e\u003cstrong\u003eACiQ 24 Volt Wiring Notice\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/aciq-mini-split-HES-warranty-12YR-Edit-2-8-4-2-1.pdf?v=1784175820\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eACiQ 2.5 Ton Ducted Air Handler Wall Mounted - R454B (ACIQ-30W-WMB)\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-WMAHU-Sub-30W-WMB-30-HPD-040725.pdf?v=1784176179\"\u003e\u003cstrong\u003e2.5 Ton HPD \/ WMB Submittal\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-WMAHU-Sub-30W-WMB-30-EHPD-102024.pdf?v=1784176185\"\u003e\u003cstrong\u003e2.5 Ton EHPD \/ WMB Submittal\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-CIS-W-WMB-im-en-01-040625_16123100000988.pdf?v=1784175944\"\u003e\u003cstrong\u003eWall-Mount Air Handler Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-CIS-W-WMB-om-en-01-093024_16123100001008.pdf?v=1784175950\"\u003e\u003cstrong\u003eWall-Mount Air Handler Owner's Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-CIS-W-WMB-sm-en-01-123124_NA_H_241231.pdf?v=1784175969\"\u003e\u003cstrong\u003eWall-Mount Air Handler Service Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-30W-WMB-30-HPD-EPT-en-01-111224.pdf?v=1784176190\"\u003e\u003cstrong\u003e2.5 Ton HPD \/ WMB Performance Table\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-30W-WMB-30-EHPD-EPT-en-01-102024.pdf?v=1784176197\"\u003e\u003cstrong\u003e2.5 Ton EHPD \/ WMB Performance Table\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-W-PB-W-WMB-Remote-Controller-Manual.pdf?v=1784175902\"\u003e\u003cstrong\u003eRemote Controller Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ACiQ","offers":[{"title":"Default Title","offer_id":67373840040240,"sku":"ACIQ-30-HPD \/ ACIQ-30W-WMB","price":3240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-30-HPD_ACIQ-30W-WMB.webp?v=1784179921","url":"https:\/\/hvacstore.com\/products\/aciq-2-5-ton-17-5-seer2-extreme-wall-mount-heat-pump-split-inverter-r454b","provider":"HVAC Store","version":"1.0","type":"link"}