{"product_id":"aciq-2-ton-15-2-seer2-central-heat-pump-split-system-inverter-r32","title":"ACiQ 2 Ton 15.2 SEER2 Central Heat Pump Split System Inverter R32","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACiQ 2 Ton 15.2 SEER2 Central Heat Pump Condenser R32 Inverter ACIQ-24TD-HP32\u003c\/h3\u003e\n\u003cp\u003eThe ACIQ-24TD-HP32 is a 2-ton heat pump condenser engineered to provide optimal comfort year-round. Built with advanced inverter technology and a 15.2 SEER2 efficiency rating, this unit delivers reliable heating and cooling performance for homeowners seeking dependable, energy-conscious comfort.\u003c\/p\u003e\n\u003cp\u003eEngineered for consistent operation and enhanced indoor comfort, this condenser adjusts output automatically based on real-time demand. The result is improved temperature stability and greater energy efficiency compared to traditional single-stage systems.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 ton heat pump condenser for residential HVAC systems\u003c\/li\u003e\n\u003cli\u003e15.2 SEER2 energy-efficient performance\u003c\/li\u003e\n\u003cli\u003eTwo-stage condenser operation for enhanced comfort control\u003c\/li\u003e\n\u003cli\u003eVariable-speed inverter compressor adjusts to real-time heating and cooling demand\u003c\/li\u003e\n\u003cli\u003ePre-charged with R32 refrigerant\u003c\/li\u003e\n\u003cli\u003eDelivers approximately 61% heating output at outdoor temperatures as low as 0°F\u003c\/li\u003e\n\u003cli\u003eRated for outdoor heating operation down to -4°F\u003c\/li\u003e\n\u003cli\u003eField-installable filter drier included\u003c\/li\u003e\n\u003cli\u003eIdeal for new installations or central HVAC system replacements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Overview\u003c\/h3\u003e\n\u003cp\u003eWith a 2-ton capacity, the ACIQ-24TD-HP32 is generally suitable for heating and cooling a small home in ideal climate conditions. In many system configurations, the indoor coil or air handler paired with this condenser may be rated at a slightly higher tonnage to help maintain optimal efficiency and airflow balance. Depending on climate, performance at lower outdoor temperatures should be considered when selecting the right system — at 0°F, this heat pump operates at approximately 61% efficiency, making it well suited for moderate climates that experience occasional cold weather.\u003c\/p\u003e\n\u003cp\u003ePlease note that this condenser cannot operate independently and must be installed with a compatible indoor air handler or evaporator coil.\u003c\/p\u003e\n\u003ch3\u003eImportant Refrigerant Safety Notice\u003c\/h3\u003e\n\u003cp\u003eThis condenser uses R32 refrigerant, classified as an A2L refrigerant. To comply with safety standards and maintain warranty coverage, the unit must be paired with an R32-compatible air handler or evaporator coil equipped with a refrigerant leak detection system. Failure to follow these requirements may result in safety hazards and could void the manufacturer warranty. For compatibility questions, please call 1-888-557-9206.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eACiQ 2 Ton Inverter Central Air Handler 21\" Width R32 ACIQ-24TD-AH32\u003c\/h3\u003e\n\u003cp\u003eThe ACIQ-24TD-AH32 is a 2-ton central ducted air handler designed to deliver consistent airflow, reliable comfort, and long-lasting performance. Equipped with a multi-speed constant torque blower motor, this unit helps maintain balanced temperatures throughout your home while operating efficiently and quietly.\u003c\/p\u003e\n\u003cp\u003eDesigned for flexibility and ease of installation, this air handler pairs seamlessly with compatible heat pump condensers and supports modern R32 refrigerant systems, making it an excellent choice for energy-efficient HVAC applications.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 ton central ducted air handler for residential systems\u003c\/li\u003e\n\u003cli\u003eCompatible with standard 24V thermostats\u003c\/li\u003e\n\u003cli\u003eMulti-speed constant torque blower motor for improved airflow efficiency\u003c\/li\u003e\n\u003cli\u003eConfigurable for upflow or horizontal-right installation\u003c\/li\u003e\n\u003cli\u003eR32 refrigerant compatibility for modern heat pump systems\u003c\/li\u003e\n\u003cli\u003eSupports optional 5 kW or 10 kW electric heat kits for supplemental or backup heating\u003c\/li\u003e\n\u003cli\u003eDurable outer cabinet construction for long-term reliability\u003c\/li\u003e\n\u003cli\u003eQuiet operation at approximately 49 decibels for enhanced indoor comfort\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Overview\u003c\/h3\u003e\n\u003cp\u003eRated at 2 tons, the ACIQ-24TD-AH32 is built to support small residential heating and cooling applications when paired with a compatible condenser. While the air handler requires an outdoor unit to operate as part of a complete system, it can also accommodate optional 5 kW or 10 kW electric heat kits to provide supplemental electric heating in heat pump configurations.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Durability\u003c\/h3\u003e\n\u003cp\u003eTo maximize installation flexibility, this air handler can be configured in upflow or horizontal-right orientations to fit a variety of residential setups. Its reinforced outer cabinet is engineered for strength and durability, helping protect internal components and ensure dependable, long-term performance.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/hvacstore.com\/collections\/heat-pump-split-systems\" title=\"Heat Pump Split Systems\"\u003e\u003cstrong\u003eView More Heat Pump Split Systems\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACiQ 2 Ton 15.2 SEER2 Central Heat Pump Condenser R32 Inverter ACIQ-24TD-HP32\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%; text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003eACiQ\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003eACIQ-24TD-HP32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003e127.9 lbs\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003e63.5 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003eR32\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003eTonnage\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003e2 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003e24,000 BTU\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003e24,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eSEER2\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003e15.2\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003e8.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eEER2\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003e10\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003eCondenser Stages\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003eTwo Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003eRotary\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003eElectric Heat\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003eHeat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eLiquid Valve Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003e3\/8\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003eSuction Valve Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003e208\/230v 1 Phase 60 Hz\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003e25 Amps\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003eMin Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003e16 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003e24 15\/16\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003e29 1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003e29 1\/8\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003eDecibel Level\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003e67 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eMin\/Max Outdoor Temp (Heating)\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 25.8434%;\"\u003e-4°F - 80°F\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 27.1144%;\"\u003eMin\/Max Outdoor Temp (Cooling)\u003c\/td\u003e\n\u003ctd style=\"height: 50px; width: 20.235%;\"\u003e5°F - 125°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"height: 50px; width: 73.1928%;\"\u003e-4°F - 125°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; width: 26.747%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"height: 50px; width: 73.1928%;\"\u003e12 Years Compressor and 7 Years Parts with Online Registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eACiQ 2 Ton Inverter Central Air Handler 21\" Width R32 ACIQ-24TD-AH32\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%; text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACiQ\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACIQ-24TD-AH32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e130.1 lbs\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eTonnage\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e2 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eR32\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eUpflow\/Horizontal-Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMaximum CFM\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e990\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHorsepower\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e1\/5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectric Backup Heat Capabilities\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e5 Kilowatts, 10 Kilowatts\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eFilter Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e18\" x 20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eLiquid Line\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/8\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSuction Line\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e208\/230v 1 Phase 60 Hz\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eFlare to Braze\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDecibel Level\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e49 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e46 1\/2\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"height: 50px;\"\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"height: 50px;\"\u003e7 Years Parts with Online Registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACiQ 2 Ton 15.2 SEER2 Central Heat Pump Condenser R32 Inverter ACIQ-24TD-HP32\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; text-align: center; border: 1px solid black; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eWarranty Type\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eCompressor\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eParts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eRegistered Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e12 years\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e7 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eACiQ 2 Ton Inverter Central Air Handler 21\" Width R32 ACIQ-24TD-AH32\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; text-align: center; border: 1px solid black; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eWarranty Type\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eParts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eRegistered Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e7 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACiQ 2 Ton 15.2 SEER2 Central Heat Pump Condenser R32 Inverter ACIQ-24TD-HP32\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-AHRI-CISTD-24TD-AH32-24TD-HP32-040926.pdf?v=1784102816\"\u003e\u003cstrong\u003eAHRI Certificate\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-R32-TDHP32-AH32-Sub-24TD-AH32-24TD-HP32-012626.pdf?v=1784102824\"\u003e\u003cstrong\u003eSubmittal\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-R32-TDHP-HP32-im-om-en-01-022426.pdf?v=1784102838\"\u003e\u003cstrong\u003eInstallation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-R32-TDHP-AH32-HP32-sm-en-01-032626.pdf?v=1784102849\"\u003e\u003cstrong\u003eService Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eACiQ 2 Ton Inverter Central Air Handler 21\" Width R32 ACIQ-24TD-AH32\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-AHRI-CISTD-24TD-AH32-24TD-HP32-040926.pdf?v=1784102816\"\u003e\u003cstrong\u003eAHRI Certificate\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-R32-TDHP32-AH32-Sub-24TD-AH32-24TD-HP32-012626.pdf?v=1784102824\"\u003e\u003cstrong\u003eSubmittal\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-R32-TDHP-AH32-im-om-en-01-022426.pdf?v=1784104520\"\u003e\u003cstrong\u003eInstallation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-R32-TDHP-AH32-HP32-sm-en-01-032626.pdf?v=1784102849\"\u003e\u003cstrong\u003eService Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ-TDAH-EHK-im-om-en-01-080625_5kW-20kW_89179cb9-16eb-4dcb-9d5d-72534080197f.pdf?v=1784104526\"\u003e\u003cstrong\u003eHeat Kit Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ACiQ","offers":[{"title":"Default Title","offer_id":67369733849392,"sku":"ACIQ-24TD-HP32 \/ ACIQ-24TD-AH32","price":3100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-24TD-HP32_ACIQ-24TD-AH32.webp?v=1784085703","url":"https:\/\/hvacstore.com\/products\/aciq-2-ton-15-2-seer2-central-heat-pump-split-system-inverter-r32","provider":"HVAC Store","version":"1.0","type":"link"}