{"product_id":"aciq-3-ton-14-3-seer2-heat-pump-split-system-multi-positional-r32","title":"ACiQ 3 Ton 14.3 SEER2 Heat Pump Split System Multi-Positional R32","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\u003chr\u003e\u003ch3\u003eACiQ 3 Ton 14.3 SEER2 Central Heat Pump Condenser Single Stage R32 AC-I-36HP14\u003c\/h3\u003e\u003cp\u003eThe AC-I-36HP14 is a 3 Ton single-stage heat pump condenser built around a scroll compressor, rated for 34,200 BTU of cooling and 34,200 BTU of heating at 14.3 SEER2 \/ 7.5 HSPF2. It ships pre-charged with enough R454B refrigerant for a 15-foot line set, so a straightforward line-set connection is all that's needed to bring the system online.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 Ton Scroll Compressor\u003c\/strong\u003e - Single-stage cooling and heat pump heating rated at 14.3 SEER2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34,200 BTU Cooling \/ 34,200 BTU Heating\u003c\/strong\u003e - Sized for mobile and manufactured home split systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Pre-Charged\u003c\/strong\u003e - Comes charged for a 15-foot line set, simplifying installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208\/230V, 1 Phase, 60 Hz Electrical\u003c\/strong\u003e - Runs on a standard single-phase circuit with a 151 lb cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR454B Refrigerant\u003c\/strong\u003e - Uses the lower-GWP refrigerant required for current equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Pump Operation\u003c\/strong\u003e - Provides both cooling and supplemental electric-backup-free heating down to roughly 35°F outdoor temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch3\u003eACiQ 3.0 Ton Multi-Positional Air Handler R32 AC-I-36AH14\u003c\/h3\u003e\u003cp\u003eThe AC-I-36AH14 is a 3 Ton multi-positional air handler rated for 34,200 BTU of airflow capacity, built to pair with a compatible ACiQ heat pump condenser. A Variable Speed ECM blower and a factory-installed TXV kit make it a flexible fit for upflow, downflow, or horizontal installations.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 Ton Multi-Positional Design\u003c\/strong\u003e - Installs upflow, downflow, or horizontal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable Speed ECM\u003c\/strong\u003e - Delivers consistent airflow and quieter operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory TXV Kit\u003c\/strong\u003e - Pre-installed for accurate refrigerant metering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Electric Backup Heat\u003c\/strong\u003e - Supports 5\/8\/10\/15\/20 kW heat kits, sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e142.6 lb Cabinet\u003c\/strong\u003e - One-piece outer casing with a corrosion-resistant aluminum coil.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant Refrigerant Safety Notice:\u003c\/strong\u003e This system uses R32, an A2L mildly flammable refrigerant. The condenser is matched with a compatible, leak-detection-equipped indoor coil\/air handler to meet current safety standards. Please call 1-888-557-9206 with any compatibility questions before installation.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacstore.com\/collections\/heat-pump-condensers\" title=\"View more Heat Pump Systems\"\u003e\u003cstrong\u003eView More Heat Pump Systems\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003chr\u003e\u003ch3\u003eACiQ 3 Ton 14.3 SEER2 Central Heat Pump Condenser Single Stage R32 AC-I-36HP14\u003c\/h3\u003e\u003ctable style=\"border-collapse: collapse; width: 100%; text-align: center;\" border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACiQ\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eAC-I-36HP14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eUPC\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e810175555898\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e34,200 BTU\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e34,200 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e59\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e7.5\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSEER2 (Efficiency)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e14.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eEER2\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e11.7\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCondenser Stages\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eSingle Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eRotary\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eLiquid Valve Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSuction Valve Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e208\/230V, 1 Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e30 Amps\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e25 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eTonnage\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3 Ton\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin\/Max Outdoor Temp for Heating\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e-4°F to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin\/Max Outdoor Temp for Cooling\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e23°F to 125.6°F\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eFlare to Braze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e25\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e29.13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e29.13\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003chr\u003e\u003ch3\u003eACiQ 3.0 Ton Multi-Positional Air Handler R32 AC-I-36AH14\u003c\/h3\u003e\u003ctable style=\"border-collapse: collapse; width: 100%; text-align: center;\" border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACiQ\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eAC-I-36AH14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eUPC\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e613365025603\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e142.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e34,200 BTU\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e34,200 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBlower\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eVariable Speed ECM\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMaximum CFM\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e50\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eOptional Electric Heat\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e5, 8, 10, 15, or 20 Kilowatts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eR32\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eFilter Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e19\" x 20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eLiquid Line Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/8\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSuction Line Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e208\/230V, 1 Phase, 60 Hz\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e6 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e5.0 Amps\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eTonnage\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eFlared\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e49\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e21.02\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e21.02\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWarranty\u003c\/h2\u003e\u003chr\u003e\u003ch3\u003eACiQ 3 Ton 14.3 SEER2 Central Heat Pump Condenser Single Stage R32 AC-I-36HP14\u003c\/h3\u003e\u003ctable style=\"width: 100%; text-align: center; border: 1px solid black; border-collapse: collapse;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eWarranty Type\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eParts\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eCompressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eStandard Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e5 years\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eRegistered Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e7 years\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003chr\u003e\u003ch3\u003eACiQ 3.0 Ton Multi-Positional Air Handler R32 AC-I-36AH14\u003c\/h3\u003e\u003ctable style=\"width: 100%; text-align: center; border: 1px solid black; border-collapse: collapse;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eWarranty Type\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eParts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eStandard Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e7 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003chr\u003e\u003ch3\u003eACiQ 3 Ton 14.3 SEER2 Central Heat Pump Condenser Single Stage R32 AC-I-36HP14\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACIQ-AC-I-AH14-HP14-Sub-AC-I-36AH14-AC-I-36HP14-051526.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eHP14\/AH14 Submittal\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ-R32-AC-I-AC14-HP14-18K-60K-im-om-en-01-051426.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCondenser Install \u0026amp; Owner's Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ-Pro-Series-Warranty-v2.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCondenser Warranty Certificate\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003chr\u003e\u003ch3\u003eACiQ 3.0 Ton Multi-Positional Air Handler R32 AC-I-36AH14\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/AC-I-36AH14-Submittal.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eAir Handler Submittal\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACIQ-AC-I-AH14-HP14-Sub-36AH14-36HP14-051526.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eHP14\/AH14 Combined Submittal\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ-R32-DAHU-AC-I-AH14-18K-60K-im-om-051526(602035000124).pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eAir Handler Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ-Pro-Series-Warranty-v2.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eAir Handler Warranty Certificate\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ACiQ","offers":[{"title":"Default Title","offer_id":67791556084016,"sku":"AC-I-36HP14 \/ AC-I-36AH14","price":2849.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/AC-I-36HP14_AC-I-36AH14.webp?v=1789526512","url":"https:\/\/hvacstore.com\/products\/aciq-3-ton-14-3-seer2-heat-pump-split-system-multi-positional-r32","provider":"HVACStore.com","version":"1.0","type":"link"}