{"product_id":"aciq-3-ton-15-6-seer2-mobile-home-air-conditioner-coil-system-vertical-r454b","title":"ACiQ 3 Ton 15.6 SEER2 Mobile Home Air Conditioner \u0026 Coil System Vertical R454B","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\u003chr\u003e\u003ch3\u003eACiQ 3 Ton 15.6 SEER2 Air Conditioner Condenser Inverter 230V R454B ACIQ-36-AC-B\u003c\/h3\u003e\u003cp\u003eThe ACIQ-36-AC-B is a 3 ton, 15.6 SEER2 air conditioner condenser built around a variable-speed inverter compressor and R454B refrigerant. Instead of cycling on and off at full capacity, the compressor speeds up and slows down to track real-time demand, and ACiQ's Learning Condenser technology monitors indoor and outdoor temperature, duct pressure, and refrigerant temperature during startup to fine-tune performance going forward.\u003c\/p\u003e\u003cp\u003eRated at 34,000 BTU of cooling with up to 3,002 CFM airflow and as low as 58 dBA of operating sound, this condenser can also throttle down to roughly a 1 ton unit when full capacity isn't needed, making it a good seasonal AC-only option for homes that already have another primary heat source such as a boiler or fireplace. It runs on a 208\/230V single-phase circuit and weighs 144.4 lbs.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Compressor\u003c\/strong\u003e - Self-adjusts BTU output to match real-time demand instead of cycling at full capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLearning Condenser Technology\u003c\/strong\u003e - Monitors temperature, duct pressure, and refrigerant temperature during startup to optimize future performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15.6 SEER2 Efficiency\u003c\/strong\u003e - Rated 15.6 SEER2 \/ 10.2 EER2 for lower cooling operating costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34,000 BTU Cooling Capacity\u003c\/strong\u003e - Delivers 34,000 BTU of cooling with up to 3,002 CFM of airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation\u003c\/strong\u003e - Runs as low as 58 dBA, noticeably quieter than a fixed-speed condenser at full load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR454B Refrigerant\u003c\/strong\u003e - Uses the lower-GWP R454B refrigerant charge required for current equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDown to 1 Ton Operation\u003c\/strong\u003e - Inverter design lets the compressor throttle down for seasonal AC-only supplemental cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208\/230V Single-Phase Electrical\u003c\/strong\u003e - Runs on a 208\/230V 1-phase 60 Hz circuit with a 25 Amps max breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant Refrigerant Safety Notice:\u003c\/strong\u003e This unit uses R454B, an A2L mildly flammable refrigerant. It must be paired with a compatible, A2L-rated indoor coil or air handler equipped with proper leak detection. Please call 1-888-557-9206 with any compatibility questions before purchasing or installing.\u003c\/p\u003e\u003chr\u003e\u003ch3\u003eACiQ 3 Ton Uncased Downflow Mobile Home Coil With TXV R454B ACIQ-MH36BU3VWEC\u003c\/h3\u003e\u003cp\u003eThe ACiQ ACIQ-MH36BU3VWEC is an uncased downflow evaporator coil built specifically for mobile and manufactured home split-system installations. It uses left-hand refrigerant and plumbing connections with sweat\/braze fittings, and a factory-installed TXV for accurate refrigerant metering.\u003c\/p\u003e\u003cp\u003eConstructed with rifled aluminum tubing, enhanced aluminum fins, and a heavy-duty polypropylene drain pan, this 3 ton coil is AHRI certifiable with any brand of compatible condenser and includes a downflow plate kit for straightforward field installation.\u003c\/p\u003e\u003ch3\u003eKey Features and Benefits:\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 Ton Downflow Coil\u003c\/strong\u003e\u003cbr\u003eSized for mobile and manufactured home split systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR454B Refrigerant Compatible\u003c\/strong\u003e\u003cbr\u003eBuilt for use with modern R454B split systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-Installed TXV\u003c\/strong\u003e\u003cbr\u003eEnsures precise refrigerant metering for improved efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRifled Aluminum Tubing\u003c\/strong\u003e\u003cbr\u003eEnhanced aluminum fins promote efficient heat transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeft-Hand Connections\u003c\/strong\u003e\u003cbr\u003eSweat\/braze fittings simplify field installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Polypropylene Drain Pan\u003c\/strong\u003e\u003cbr\u003eResists corrosion for long-term reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownflow Plate Kit Included\u003c\/strong\u003e\u003cbr\u003eBuilt specifically for mobile and manufactured home use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cp\u003eThis coil is designed for mobile and manufactured home applications only and must be matched with a compatible condenser and mobile home furnace or air handler cabinet; it cannot operate as a standalone unit. Disclaimer: This coil is intended for use with R454B refrigerant systems, which are classified as A2L. To comply with safety standards, ensure the paired condenser and system include proper leak detection where required. Please call us at 1-888-557-9206 if you have any questions.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/hvacstore.com\/collections\/heat-pump-condensers\"\u003e\u003cstrong\u003eView More Heat Pump Systems\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003chr\u003e\u003ch3\u003eACiQ 3 Ton 15.6 SEER2 Air Conditioner Condenser Inverter 230V R454B ACIQ-36-AC-B\u003c\/h3\u003e\u003ctable style=\"border-collapse: collapse; width: 100%; text-align: center;\" border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACiQ\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACIQ-36-AC-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e144.4\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eUPC\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e810175553597\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e34,000 BTU\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMaximum CFM\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e58\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSEER2 (Efficiency)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e15.6\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eEER2\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e10.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCondenser Stages\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eVariable Speed\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eRotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eLiquid Line\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/8\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSuction Line\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e208\/230V 1 Phase 60 Hz\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e25 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e25 Amps\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eTonnage\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eZone Compatibility\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eSingle Zone\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eOperating Mode\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eCooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e31.89\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e37.24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e16.14\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eACiQ 3 Ton Uncased Downflow Mobile Home Coil With TXV R454B ACIQ-MH36BU3VWEC\u003c\/h3\u003e\u003ctable style=\"border-collapse: collapse; width: 100%; text-align: center;\" border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACiQ\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACIQ-MH36BU3VWEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e25\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eR454B\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eTonnage\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e19 1\/2\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e17 3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e19 5\/8\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e10 Year Limited Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eWarranty\u003c\/h2\u003e\u003chr\u003e\u003ch3\u003eACiQ 3 Ton 15.6 SEER2 Air Conditioner Condenser Inverter 230V R454B ACIQ-36-AC-B\u003c\/h3\u003e\u003ctable style=\"width: 100%; text-align: center; border: 1px solid black; border-collapse: collapse;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eWarranty Type\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eParts\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eCompressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eStandard Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e5 years\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eRegistered Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e7 years\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e12 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eACiQ 3 Ton Uncased Downflow Mobile Home Coil With TXV R454B ACIQ-MH36BU3VWEC\u003c\/h3\u003e\u003ctable style=\"border-collapse: collapse; width: 100%; text-align: center;\" border=\"1\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWarranty Type\u003c\/th\u003e\n\u003cth style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eParts\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"height: 50px;\"\u003eRegistered Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e10 Years Limited\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eDocuments\u003c\/h2\u003e\u003chr\u003e\u003ch3\u003eACiQ 3 Ton 15.6 SEER2 Air Conditioner Condenser Inverter 230V R454B ACIQ-36-AC-B\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/Cooling%20Only%20Mode%20-%20Wiring%20Guide.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCooling Only Wiring Guide\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ-AC-B-im-en-01-030226-install-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eInstallation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/User's%20Manual%20Ducted%20ACiQ.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eOwner's Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ-AC-B-sm-en-01-020526-service-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eService Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/aciq-warranty-12YR-edit.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eWarranty Information\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACIQ_24v_Warning_2025_v1.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eACiQ 24 Volt Wiring Notice\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eACiQ 3 Ton Uncased Downflow Mobile Home Coil With TXV R454B ACIQ-MH36BU3VWEC\u003c\/h3\u003e\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/hvacdirect.com\/media\/pdf\/Aspen%20R32-R454B%20Coil%20Installation%20Guide.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/hvacdirect.com\/media\/pdf\/Aspen%20R32-R454B%20Copper%20Coil%20Spec%20Sheet.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eSpecifications Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ-Mobile-Home-Warranty-V2.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eWarranty Information\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ACiQ","offers":[{"title":"Default Title","offer_id":67820584468784,"sku":"ACIQ-36-AC-B-MH \/ ACIQ-MH36BU3VWEC","price":2933.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACIQ-36-AC-B-MH_ACIQ-MH36BU3VWEC.webp?v=1789960503","url":"https:\/\/hvacstore.com\/products\/aciq-3-ton-15-6-seer2-mobile-home-air-conditioner-coil-system-vertical-r454b","provider":"HVACStore.com","version":"1.0","type":"link"}