{"product_id":"aciq-96-100-000-btu-gas-furnace-two-stage-upflow-horizontal-21-width","title":"ACiQ 96% 100,000 BTU Gas Furnace Two Stage Upflow\/Horizontal 21\" Width","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACiQ 96% 100,000 BTU Gas Furnace Two Stage Upflow\/Horizontal 21\" Width AC-F100-96M2C\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eACiQ AC-F100-96M2C\u003c\/strong\u003e is a high efficiency two stage condensing gas furnace that turns 96% of its fuel into usable heat. Rated at a \u003cstrong\u003e100,000 BTU heating input\u003c\/strong\u003e with 95,000 BTU of output on high fire, it also runs a low fire stage of 70,000 BTU input (67,000 BTU output) on milder days, holding more even temperatures with fewer on and off cycles. The variable speed constant air volume ECM blower keeps airflow steady across different duct resistances, and a quiet two speed induced draft blower handles venting. Built for \u003cstrong\u003eupflow and horizontal installation\u003c\/strong\u003e (left or right), it suits basements and side mounted setups and is a general fit for homes of roughly 2,200 to 2,600 square feet. A propane conversion kit is included, and Low NOx burners keep emissions below 40 ng\/J.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100,000 BTU Input \/ 95,000 BTU Output\u003c\/strong\u003e - High fire heating capacity, a general estimate for 2,200 to 2,600 sq. ft. homes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Fire Stage 70,000 BTU Input \/ 67,000 BTU Output\u003c\/strong\u003e - Runs at reduced capacity on milder days for longer, quieter and more even heating cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e96% AFUE High Efficiency\u003c\/strong\u003e - Converts 96% of the fuel energy into usable heat and cuts energy waste compared with standard efficiency furnaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo Stage Gas Valve\u003c\/strong\u003e - Matches heat output to demand instead of running at full fire every cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable Speed ECM Blower (1 HP)\u003c\/strong\u003e - Constant air volume control keeps airflow stable with 5 speed modes and low continuous fan options for quiet circulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpflow and Horizontal Installation\u003c\/strong\u003e - Installs upflow or horizontal left or right. Downflow installation is not supported.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless Steel Secondary Heat Exchanger\u003c\/strong\u003e - Paired with a heavy duty aluminized steel tubular primary heat exchanger for long service life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo Speed Induced Draft Blower\u003c\/strong\u003e - Quiet venting matched to each burner stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePVC Venting (2\" or 3\")\u003c\/strong\u003e - Easy to install top venting with optional side venting. Metal flue venting is not permitted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLP Conversion Kit Included\u003c\/strong\u003e - Factory set for natural gas and converts to propane with the included kit, installed by a qualified technician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow NOx Burners\u003c\/strong\u003e - NOx emissions below 40 ng\/J. See the installation restrictions below.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf Diagnostic Control Board\u003c\/strong\u003e - Constant memory fault code history reported on an LED for faster troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Ready (3.5 to 5 Tons)\u003c\/strong\u003e - Supports matched ACiQ air conditioner or heat pump coils at 0.5\" ESP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21\" Industry Standard Cabinet\u003c\/strong\u003e - Heavy gauge insulated steel cabinet with left or right gas and electrical entry and an easy cut bottom or side return.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified and ETL Listed\u003c\/strong\u003e - Rated performance you can verify by AHRI certificate number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePair the \u003cstrong\u003eACiQ AC-F100-96M2C\u003c\/strong\u003e with an ACiQ condenser or heat pump and a matching coil for an efficient year round system. With its 21\" cabinet, two stage comfort and 96% efficiency, it is a strong upgrade for upflow and horizontal replacements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLow NOx furnace. This furnace cannot be installed in Colorado or in the following California counties: Fresno, San Joaquin, Kern, Kings, Los Angeles, Madera, Merced, Orange, Riverside, San Bernardino, Stanislaus, Yolo and Tulare. These areas require an Ultra Low NOx furnace. Contact us with any questions.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/hvacstore.com\/collections\/furnaces\" title=\"Furnaces\"\u003e\u003cstrong\u003eView More Furnaces\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACiQ 96% 100,000 BTU Gas Furnace Two Stage Upflow\/Horizontal 21\" Width AC-F100-96M2C\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%; text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eACiQ\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eAC-F100-96M2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e162\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e218667908\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eUPC\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e810175556611\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eExhaust Flue Requirement\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003ePlastic \/ PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eFurnace Efficiency \/ AFUE\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e96%\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHigh Fire Input \/ Output\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e100,000 \/ 95,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eLow Fire Input \/ Output\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e70,000 \/ 67,000 BTU\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBurner Stages\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eNumber of Burners\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eBlower Motor\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eVariable Speed ECM, 5 Speed Modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHorsepower\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e1 HP\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMotor RPM\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e1050 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e115V 1 Phase 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMin. Circuit Ampacity\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e13.9 Amps\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e25 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eTemperature Rise Range\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e35 to 65 F\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCooling Match Range\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e3.5 to 5 Tons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eVent Diameter\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e2\" or 3\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eIgnition Type\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eDirect Ignition with Silicon Nitride Hot Surface Ignitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eFuel Type\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003ePropane, Natural Gas\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eNOx Rating\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eLow NOx (below 40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eLP Conversion Kit\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eIncluded\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eCabinet Width\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e33 3\/4\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003e28 3\/4\"\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eSecondary Heat Exchanger\u003c\/td\u003e\n\u003ctd style=\"height: 50px;\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"height: 50px;\"\u003e20 Year Heat Exchanger and 10 Year Parts with Online Registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACiQ 96% 100,000 BTU Gas Furnace Two Stage Upflow\/Horizontal 21\" Width AC-F100-96M2C\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; text-align: center; border: 1px solid black; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eWarranty Type\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eParts\u003c\/td\u003e\n\u003ctd style=\"background-color: lightgray; font-weight: bold; height: 50px; border: 1px solid black;\"\u003eHeat Exchanger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eStandard Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e5 years\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003eRegistered Warranty\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e10 years\u003c\/td\u003e\n\u003ctd style=\"height: 50px; border: 1px solid black;\"\u003e20 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eACiQ 96% 100,000 BTU Gas Furnace Two Stage Upflow\/Horizontal 21\" Width AC-F100-96M2C\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/AC-F_96M2_Installation_and_Owners_Manual.pdf?v=1794551072\"\u003e\u003cstrong\u003eACiQ AC-F 96M2 Installation and Owner's Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/AC-F_96M2_Specifications_Sheet.pdf?v=1794551077\"\u003e\u003cstrong\u003eACiQ AC-F 96M2 Specifications Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/AC-F_96M2_LP_Conversion_Kit_Installation_Manual.pdf?v=1794551081\"\u003e\u003cstrong\u003eACiQ AC-F 96M2 LP Conversion Kit Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ_AC-F_Furnace_Warranty.pdf?v=1794551085\"\u003e\u003cstrong\u003eACiQ AC-F Furnace Warranty\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ACiQ","offers":[{"title":"Default Title","offer_id":68437150466352,"sku":"AC-F100-96M2C","price":2500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/1494\/6352\/files\/ACiQ_AC-F100-96M2C.webp?v=1794592403","url":"https:\/\/hvacstore.com\/products\/aciq-96-100-000-btu-gas-furnace-two-stage-upflow-horizontal-21-width","provider":"HVACStore.com","version":"1.0","type":"link"}