Skip to content
July Sale Is Live! | Click Or Call 833-658-3387

ACiQ 2 Ton 16 SEER2 Ceiling Mount Heat Pump Split System Inverter R454B

By ACiQ | Model: ACIQ-24-EHPD / ACIQ-24W-PB | ID: 91823
No Sales Tax - in most states excluding California
Manufacturer Warranty Included
Satisfaction Guarantee - or return within 30 Days
Most Products In Stock - Call or Text (833) 658-3387 for availability
$2,720.00 + FREE SHIPPING

ADD TO CART FOR BEST PRICE

Important Installation Note: This is a professional-grade, non-DIY system (including ACiQ, Goodman, Daikin, and select MrCool systems). It's recommended that installation and configuration is done by a licensed HVAC technician to ensure correct setup, safety compliance, and to maintain your manufacturer warranty coverage.

Product Details

ACIQ Standard Series 2 Ton 18.1 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter (ACIQ-24-EHPD)

Inverter - The ACIQ-24-EHPD 2 ton central inverter heat pump utilizes inverter technology to convert AC power to DC, allowing the compressor to adjust its speed. This enables the condenser to modify its BTU output based on the current demand, providing efficient and adaptable performance throughout varying weather conditions.

Learning Condenser - Equipped with advanced sensors, this condenser monitors indoor and outdoor air temperature, duct pressure, refrigerant temperature, and overall performance. During the initial startup, it enters a learning mode, optimizing future operations for maximum efficiency by collecting and storing data.

Adaptive Sizing - With its self-adjusting inverter design, the ACIQ-24-EHPD can be sized based on your heating needs. Standard heat pumps may cause discomfort during summer when sized for heat, but this unit automatically adjusts to function like a smaller unit, ensuring ideal cooling performance without excess humidity.

Key Features

  • Variable output based on demand: 12,000-24,000 BTU for cooling, 12,000-26,000 BTU for heating
  • R454B refrigerant
  • Inverter heat pump system for ducted applications
  • Efficient cooling from -13°F to 122°F outdoor temperatures
  • Reliable heating from -13°F to 75°F outdoor temperatures
  • Durable gold fin condenser coil coating for longevity
  • Quiet operation, even under high workloads

Performance Overview

Boasting an efficiency rating of 18.1 SEER2, the ACIQ-24-EHPD provides versatile comfort across a range of climates by providing reliable comfort with a variable output that eliminates short cycling for lasting efficiency. At 0°F, this heat pump operates at 81% efficiency, making it a good fit for maximizing efficiency in the coldest climates.

Important Refrigerant Safety Notice: This unit uses R454B, an A2L (mildly flammable) refrigerant. It must be paired with a compatible indoor unit equipped with the appropriate leak-detection safety measures. Please call 1-888-557-9206 with any compatibility questions before purchasing or installing.


ACIQ 2 Ton Ducted Air Handler Ceiling Mounted - R454B (ACIQ-24W-PB)

The ACIQ Ceiling Mounted Ducted Air Handler, commonly known as the "pancake" air handler, is specifically engineered for use with R454B refrigerant. It is well-suited for installation in drop ceilings and attic spaces and connects directly to ductwork. Designed to pair seamlessly with ACIQ High Efficiency inverter systems, this unit delivers optimal efficiency and quiet operation. Durably built with galvanized-steel construction and offering easy service access, it provides dependable performance. A 7-year parts warranty is included with online registration, ensuring lasting peace of mind.

Key Features

  • Connects to ductwork
  • Suitable for use with R454B refrigerant
  • Variable speed motor for ultimate efficiency
  • Quiet operation
  • Galvanized-steel construction
  • Easy service access
  • 7-Year Parts Warranty with Online Registration
  • Works with our high-efficiency inverter condensers

Performance Overview

This ceiling-mounted air handler is equipped with a variable-speed blower capable of up to 824 Maximum CFM at a quiet 56.5 dBA, and supports optional electric backup heat kits (3kW, 5kW, 8kW, or 10kW) for supplemental heating. Pairs directly with the ACIQ-24-EHPD condenser above to form a complete R454B ducted heat pump system, ideal for multi-tenant and drop-ceiling installations.

View More Multi Tenant Heat Systems

Specifications

ACIQ Standard Series 2 Ton 18.1 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter (ACIQ-24-EHPD)

Brand ACiQ Model ACIQ-24-EHPD
Feature Spec SKU ACIQ-24-EHPD
Refrigerant Charge 74.08 oz. Weight (in lbs) 109.13
Brand/Manufacturer ACiQ Replaces ACiQ-24-EHPB
Cooling BTU 24,000 BTU Heating BTU 26,000 BTU
Maximum CFM 1765.7 Decibel Level (dBA) 60
Electric Heat Heat Pump Refrigerant R454B
HSPF2 9.7 SEER2 (Efficiency) 18.1
EER2 11.0 Condenser Stages Variable Speed
Compressor Type Rotary Liquid Valve Size 3/8"
Suction Valve Size 3/4" Electrical 208/230V, 1 Phase, 60 Hz
Phase Single Phase Max Breaker Size 20 Amps
Min. Breaker Size 19 Amps Tonnage 2 Ton
Min/Max Outdoor Temp for Heating -13°F - 75°F Min/Max Outdoor Temp for Cooling -13°F - 122°F
Ambient Temperature Range -13°F - 122°F Height 26.50"
Width 35.04" Depth 13.46"
Warranty 12 Years Compressor and 7 Years Parts with Online Registration

ACIQ 2 Ton Ducted Air Handler Ceiling Mounted - R454B (ACIQ-24W-PB)

Brand ACiQ Model ACIQ-24W-PB
Feature Spec SKU ACIQ-24W-PB
Weight (in lbs) 136.5 Brand/Manufacturer ACiQ
Blower Motor Variable-Speed Maximum CFM 824
Decibel Level (dBA) 56.5 decibels Electric Backup Heat Capabilities (Optional) 3 Kilowatts, 5 Kilowatts, 8 Kilowatts, 10 Kilowatts
Configuration Ceiling Mounted Refrigerant R454B
Liquid Line 3/8" Suction Line 3/4"
Electrical 208/230v 1 Phase 60 Hz Max Breaker Size 15 Amps
Min. Breaker Size 5 Amps Tonnage 2 Ton
Height 10.93" Width 49.13"
Depth 23.33"
Warranty 7 years parts with online registration
Warranty

ACIQ Standard Series 2 Ton 18.1 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter (ACIQ-24-EHPD)

Warranty Type Compressor Parts
Registered Warranty 12 years 7 years

ACIQ 2 Ton Ducted Air Handler Ceiling Mounted - R454B (ACIQ-24W-PB)

Warranty Type Parts
Registered Warranty 7 years
Shipping

We ship freight to the 48 contiguous states, excluding Hawaii and Alaska. Some shipping restrictions may apply. Liftgate services may incur an additional fee, which can be added at checkout.

Order Processing: Orders are processed within 1-3 business days (excluding weekends). Orders placed on Fridays will be processed the next business day. Once shipped, you’ll receive an email confirmation with tracking details. Backordered products may have longer processing times, and we will notify you of any delays.

Arrival of Goods: Freight delivery times depend on the carrier's schedule and routing. Estimated delivery times are provided at checkout. The carrier will contact you to arrange delivery, and you must be present to sign for the shipment.

Damages: Upon delivery, inspect your shipment carefully for any damage or discrepancies. Note any issues on the carrier’s delivery receipt and notify us within 24 hours. Claims made after this timeframe may be denied. Photographic proof is required for processing claims. Report damages or discrepancies immediately at [email protected].

Returns: For returns unrelated to damage, contact us at [email protected] for authorization. Return shipping costs are the customer’s responsibility, and a 20% restocking fee applies. Items must be in original packaging and condition for a refund.

Delivery Receipt: Before signing the delivery receipt, inspect the shipment for any damage. Your signature confirms acceptance of the delivery unless issues are noted.

Policy Updates: Our shipping policy may change, and updates will be communicated via our website or other channels. For any questions, contact The HVAC Store at [email protected] or call (833) 658-3387.

Reviews
Questions & Answers loading...

Our Real Customer Reviews

See what our customers have said about us.

Product Details

ACIQ Standard Series 2 Ton 18.1 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter (ACIQ-24-EHPD)

Inverter - The ACIQ-24-EHPD 2 ton central inverter heat pump utilizes inverter technology to convert AC power to DC, allowing the compressor to adjust its speed. This enables the condenser to modify its BTU output based on the current demand, providing efficient and adaptable performance throughout varying weather conditions.

Learning Condenser - Equipped with advanced sensors, this condenser monitors indoor and outdoor air temperature, duct pressure, refrigerant temperature, and overall performance. During the initial startup, it enters a learning mode, optimizing future operations for maximum efficiency by collecting and storing data.

Adaptive Sizing - With its self-adjusting inverter design, the ACIQ-24-EHPD can be sized based on your heating needs. Standard heat pumps may cause discomfort during summer when sized for heat, but this unit automatically adjusts to function like a smaller unit, ensuring ideal cooling performance without excess humidity.

Key Features

  • Variable output based on demand: 12,000-24,000 BTU for cooling, 12,000-26,000 BTU for heating
  • R454B refrigerant
  • Inverter heat pump system for ducted applications
  • Efficient cooling from -13°F to 122°F outdoor temperatures
  • Reliable heating from -13°F to 75°F outdoor temperatures
  • Durable gold fin condenser coil coating for longevity
  • Quiet operation, even under high workloads

Performance Overview

Boasting an efficiency rating of 18.1 SEER2, the ACIQ-24-EHPD provides versatile comfort across a range of climates by providing reliable comfort with a variable output that eliminates short cycling for lasting efficiency. At 0°F, this heat pump operates at 81% efficiency, making it a good fit for maximizing efficiency in the coldest climates.

Important Refrigerant Safety Notice: This unit uses R454B, an A2L (mildly flammable) refrigerant. It must be paired with a compatible indoor unit equipped with the appropriate leak-detection safety measures. Please call 1-888-557-9206 with any compatibility questions before purchasing or installing.


ACIQ 2 Ton Ducted Air Handler Ceiling Mounted - R454B (ACIQ-24W-PB)

The ACIQ Ceiling Mounted Ducted Air Handler, commonly known as the "pancake" air handler, is specifically engineered for use with R454B refrigerant. It is well-suited for installation in drop ceilings and attic spaces and connects directly to ductwork. Designed to pair seamlessly with ACIQ High Efficiency inverter systems, this unit delivers optimal efficiency and quiet operation. Durably built with galvanized-steel construction and offering easy service access, it provides dependable performance. A 7-year parts warranty is included with online registration, ensuring lasting peace of mind.

Key Features

  • Connects to ductwork
  • Suitable for use with R454B refrigerant
  • Variable speed motor for ultimate efficiency
  • Quiet operation
  • Galvanized-steel construction
  • Easy service access
  • 7-Year Parts Warranty with Online Registration
  • Works with our high-efficiency inverter condensers

Performance Overview

This ceiling-mounted air handler is equipped with a variable-speed blower capable of up to 824 Maximum CFM at a quiet 56.5 dBA, and supports optional electric backup heat kits (3kW, 5kW, 8kW, or 10kW) for supplemental heating. Pairs directly with the ACIQ-24-EHPD condenser above to form a complete R454B ducted heat pump system, ideal for multi-tenant and drop-ceiling installations.

View More Multi Tenant Heat Systems

Specifications

ACIQ Standard Series 2 Ton 18.1 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter (ACIQ-24-EHPD)

Brand ACiQ Model ACIQ-24-EHPD
Feature Spec SKU ACIQ-24-EHPD
Refrigerant Charge 74.08 oz. Weight (in lbs) 109.13
Brand/Manufacturer ACiQ Replaces ACiQ-24-EHPB
Cooling BTU 24,000 BTU Heating BTU 26,000 BTU
Maximum CFM 1765.7 Decibel Level (dBA) 60
Electric Heat Heat Pump Refrigerant R454B
HSPF2 9.7 SEER2 (Efficiency) 18.1
EER2 11.0 Condenser Stages Variable Speed
Compressor Type Rotary Liquid Valve Size 3/8"
Suction Valve Size 3/4" Electrical 208/230V, 1 Phase, 60 Hz
Phase Single Phase Max Breaker Size 20 Amps
Min. Breaker Size 19 Amps Tonnage 2 Ton
Min/Max Outdoor Temp for Heating -13°F - 75°F Min/Max Outdoor Temp for Cooling -13°F - 122°F
Ambient Temperature Range -13°F - 122°F Height 26.50"
Width 35.04" Depth 13.46"
Warranty 12 Years Compressor and 7 Years Parts with Online Registration

ACIQ 2 Ton Ducted Air Handler Ceiling Mounted - R454B (ACIQ-24W-PB)

Brand ACiQ Model ACIQ-24W-PB
Feature Spec SKU ACIQ-24W-PB
Weight (in lbs) 136.5 Brand/Manufacturer ACiQ
Blower Motor Variable-Speed Maximum CFM 824
Decibel Level (dBA) 56.5 decibels Electric Backup Heat Capabilities (Optional) 3 Kilowatts, 5 Kilowatts, 8 Kilowatts, 10 Kilowatts
Configuration Ceiling Mounted Refrigerant R454B
Liquid Line 3/8" Suction Line 3/4"
Electrical 208/230v 1 Phase 60 Hz Max Breaker Size 15 Amps
Min. Breaker Size 5 Amps Tonnage 2 Ton
Height 10.93" Width 49.13"
Depth 23.33"
Warranty 7 years parts with online registration
Warranty

ACIQ Standard Series 2 Ton 18.1 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter (ACIQ-24-EHPD)

Warranty Type Compressor Parts
Registered Warranty 12 years 7 years

ACIQ 2 Ton Ducted Air Handler Ceiling Mounted - R454B (ACIQ-24W-PB)

Warranty Type Parts
Registered Warranty 7 years
Shipping

We ship freight to the 48 contiguous states, excluding Hawaii and Alaska. Some shipping restrictions may apply. Liftgate services may incur an additional fee, which can be added at checkout.

Order Processing: Orders are processed within 1-3 business days (excluding weekends). Orders placed on Fridays will be processed the next business day. Once shipped, you’ll receive an email confirmation with tracking details. Backordered products may have longer processing times, and we will notify you of any delays.

Arrival of Goods: Freight delivery times depend on the carrier's schedule and routing. Estimated delivery times are provided at checkout. The carrier will contact you to arrange delivery, and you must be present to sign for the shipment.

Damages: Upon delivery, inspect your shipment carefully for any damage or discrepancies. Note any issues on the carrier’s delivery receipt and notify us within 24 hours. Claims made after this timeframe may be denied. Photographic proof is required for processing claims. Report damages or discrepancies immediately at [email protected].

Returns: For returns unrelated to damage, contact us at [email protected] for authorization. Return shipping costs are the customer’s responsibility, and a 20% restocking fee applies. Items must be in original packaging and condition for a refund.

Delivery Receipt: Before signing the delivery receipt, inspect the shipment for any damage. Your signature confirms acceptance of the delivery unless issues are noted.

Policy Updates: Our shipping policy may change, and updates will be communicated via our website or other channels. For any questions, contact The HVAC Store at [email protected] or call (833) 658-3387.

Reviews